Genelec S30B
System Specifications
| Lower cut-off frequency, -3 dB: | < 42 Hz | |
| Upper cut-off frequency, -3 dB: | > 25 kHz | |
| Free field frequency response tolerance of system | ± 3 dB | |
| Maximum short term sine wave acoustic output on axis in half space, integrated from 100 Hz to 3 kHz | @ 1 m > 111 dB SPL @ 0.5 m > 117 dB SPL |
|
| Maximum continuous RMS acoustic input in same conditions with IEC-weighted noise | @ 1 m > 104 dB SPL @ 0.5 m > 110 dB SPL |
|
| Maximum peak acoustic output per pair on top of console, speakers @ 1 m from the engineer, with music material | > 125 dB | |
| A -20 dBu signal input will produce 87 dB SPL in free field @ 1 m on axis with all controls set at the 'CAL' position. The 'CAL' position is the 0 dB position of all tone controls and the maximum sensitivity position of the input level control. See specification in the Crossover Section. | ||
| Input level for maximum short term output | +4 dBu | |
| Input sensitivity adjusting range continuously variable |
0...-20 dB (0 dB 'CAL') | |
| Self generated noise level in free field @ 1 m on axis | < 10 dB (A weighted) | |
| Harmonic distortion at 90 dB SPL at 1m on axis f < 200 Hz f > 200 Hz |
< 3 % < 1 % |
|
| Drivers Bass Mid Treble |
8" cone (210mm) 3 1/2" cone (80 mm) 3/8" x 2 1/2" ribbon (9x65 mm) with DCW |
|
| Weight | 44 lb. (20 kg) | |
| Dimensions Width Height Depth |
12 5/8" (320 mm) 19 1/2" (495 mm) 11" (280 mm) |
|
Amplifier |
||
| Bass amplifier output power at 8 ohm load continuous momentary |
90 W 110 W |
|
| Mid amplifier output power at 8 ohm load continuous momentary |
25 W 110 W |
|
| Treble amplifier output power at 8 ohm load continuous momentary |
8 W 90 W |
|
| Mid and treble channel continuous output power is limited by the electronic overload protection | ||
| Slew rate | > 20 V /µs | |
| Amplifier system distortion at nominal output THD SMPTE-IM CCIF-IM DIM100 |
< 0,1 % < 0,1 % < 0,1 % < 0,1 % |
|
| The amplifier system has passed the following tests: | ||
| Dry heat, stock (72 hours at +55°C, +131°F) |
IEC 68-2, Bb | |
| Dry heat, operation (20 hours at +40ºC, 104ºF) |
IEC 68-2-2, Bb | |
| Shock (1000 shocks at 25 G in each direction) |
IEC 68-2-29, Eb | |
| Vibration (from 10 to 150 Hz at 1 G, 2 hours at each direction) |
IEC 68-2-6, Fc |
|
| Damp heat, cyclic (RH 93%, 12 hours at +40°C, +104°F, 12 hours at+25°C, +77°F) |
IEC 68-2-30, Db |
|
| Cold operation (20 hours at -10°C, 14°F) |
IEC-68-2-1, Ab |
|
| Cold, stock (72 hours at -40°C, -40°F) |
IEC 68-2-1, Ab |
|
| Temperature changes (4 cycles from-40ºC to +55ºC and back from -40ºC to +131ºF) |
IEC 68-2-14, Nb | |
| Signal to Noise ratio, from shorted system input to channel output, referred to full output bass midrange treble |
98 dB 101 dB 97 dB |
|
| Mains voltage | 110/220/240 VAC | |
| Voltage operation range | ± 10 % | |
| Power consumption, idle full output |
30 VA 220 VA |
|
Crossover |
||
| Input connector: XLR female | pin 2+ pin 3- |
|
| Input impedance | 10 k balanced | |
| Subsonic filter | down 12 dB @20 Hz re 100 Hz level |
|
| Ultrasonic filter | down 12 dB @50 kHz re 10 kHz level |
|
| Crossover frequency bass / midrange midrange / treble |
420 Hz 4 kHz |
|
| Crossover acoustical slopes | > 18 dB / octave | |
| Tone control operation range in 1 dB steps bass middrange treble |
from 0 dB to -6 dB from 0 dB to -6 dB from 0 dB to -6 dB |
|
| The 0 dB position is the 'CAL' position (switch position number 7) | ||
| Bass roll-off filter in 2 dB steps | ||
| The 0 dB position is the 'CAL' position (switch position number 3) | ||
All data subject to change without prior notice |
||