Genelec 1034A
System Specifications
| Lower cut-off frequency, -3 dB: | < 35 Hz | |
| Upper cut-off frequency, -3 dB: | > 22 kHz | |
| Free field frequency response tolerance of system | ± 3 dB | |
| Maximum sine wave acoustic output @ 1m on axis in a half space | ||
| continuous (thermally limited) |
> 120 dB SPL | |
| short-term (200 ms, amplifier output voltage limited) |
> 125 dB SPL | |
| Maximum continuous RMS acoustic output in same conditions with IEC-weighted noise | > 121 dB SPL | |
| Maximum peak acoustic output per pair at engineer's site, speakers @ 2 m from the engineer with music material | > 130 dB | |
| A -20 dBu signal input will produce 107 dB SPL in free field @1 m on axis with all controls set at the 'CAL' position. The 'CAL' position is the 0 dB position of all tone controls and the maximum sensitivity position of the input level control. See specification in the Crossover Section. | ||
| Self generated noise level in free field @ 2m on axis | < 20 dB (A weighted) | |
| Harmonic distortion at 100 dB SPL at 1m on axis f < 200 Hz 200 Hz < f < 4 kHz f > 4kHz |
< 1 % < 1 % < 2 % |
|
| Drivers Bass Mid Treble |
2 x 12" cone (300 mm) 5" cone (120 mm) 1" throat compression driver |
|
| Weight: Speaker Amplifier |
249 lb. (113 kg) 156 lb. (71 kg) |
|
| Dimensions, Speaker: Width Height Depth |
36 1/4" (920 mm) 27" (685 mm) 21 5/8" (550 mm) |
|
| Dimensions, Amplifier: Width Height Depth |
19" (483 mm) 29 3/4" (755 mm) 14 9/16" (370 mm) |
|
Amplifier |
||
| Bass amplifier output power at 4 ohm load: continuous momentary |
2 x 300 W 2 x 600 W |
|
| Mid amplifier output power at 8 ohm load: continuous momentary |
2 x 50 W 2 x 300 W |
|
| Treble amplifier output power at 8 ohm load: continuous momentary |
2 x 13W 2 x 300 W |
|
| Continuous output power is limited by the driver unit protection processor. | ||
| Slew rate | 100 V /µs | |
| Amplifier system distortion at nominal output THD SMTE-IM CCIF-IM DIM100 |
< 0,05 % < 0,1 % < 0,1 % < 0,1 % |
|
| Signal to Noise ratio, from shorted system input to channel output, referred to full output bass midrange treble |
101 dB 105 dB 106 dB |
|
| Mains voltage | 100/110/200/220/240 VAC | |
| Voltage operation range | ± 5 % | |
| Power consumption, idle full output |
150 VA 3500 VA |
|
Crossover |
||
| Input connector: XLR female | pin 2+ pin 3- |
|
| Input impedance | 10 kOhm balanced | |
| Continuously variable input level for maximum output: @10 dB attenuation @0 dB attenuattion |
from +8 to +18 dBu from -2 to + 8 dBu |
|
| Subsonic filter: | down 12 dB @18 Hz re 100 Hz level |
|
| Ultrasonic filter | down 12 dB@ 50 kHz re 10 kHz |
|
| Crossover frequency bass / midrange midrange / treble |
400 Hz 3,5 kHz |
|
| Tone control operation range 1 dB steps bass middle treble |
from 0 dB to -6 dB from 0 dB to -6 dB from 0 dB to -6 dB |
|
| The 0 dB position is the 'CAL' position (switch position number 7) | ||
| Bass roll-off filter in 2 dB steps: | ||
| The 0 dB position is the 'CAL' position (switch position number 3) | ||
| Bass tilt control in 2 dB steps: | ||
| The 0 dB position is the 'CAL' position (switch position number 4) | ||
All data subject to change without prior notice |
||