Genelec 1018A

System Specifications

Lower cut-off frequency, -3 dB: < 80 Hz
Upper cut-off frequency, -3 dB: > 18 kHz
Free field frequency response tolerance of system ± 4 dB
Maximum continuous sine wave acoustic output @ 1m on axis in a free field from 200 Hz to 2 kHz > 100 dB SPL
Maximum peak acoustic output per pair on top of a console, 1 m from the engineer with music material > 112 dB
A -20 dBu signal input will produce 86 dB SPL in a free field @ 1 m on axis with all controls set at the 'CAL' position. The 'CAL' position is the 0 dB position of all tone controls and the maximum sensitivity position of the input level control. See specification in the Crossover Section.
Self generated noise level in free field @ 1m on axis < 20 dB
(A weighted)
Harmonic distortion at 85 dB SPL @ 1m on axis
f < 300 Hz
f > 300 Hz
< 3%
< 1%
Horizontal treble radiation loss at 30° off axis
f = 10 kHz
f = 15 kHz
< 4 dB
< 5 dB
Drivers
Bass
Treble
4" cone (100 mm)
2" cone (50 mm)
Weight 7.7 lb (3,5 kg)
Dimensions:
Width
Height
Depth
5 7/8" (150 mm)
10 1/4" (260 mm)
6 1/4" (160 mm)

Amplifier
 
Bass amplifier output power at 8 ohm load
continuous
momentary
19 W
30 W
Treble amplifier output power at 8 ohm load
continuous
momentary
5 W
30 W
Treble channel continuous output power is limited by the electronic overload protection  
Slew rate 15 V /µs
Amplifier system distortion at nominal output
THD
SMPTE-IM
CCIF-IM
DIM100
< 0,2%
< 0,2%
< 0,2%
< 0,2%
Signal to Noise ratio, from shorted system input to channel output, referred to full output
Bass
Treble
78 dB
90 dB
Mains voltage 110/220/240 VAC
Voltage Operation Range ± 10%
Power consumption,
idle
full output
5 VA
50 VA

Crossover
 
Input connector: XLR female pin 2+
pin 3-
To feed from unbalanced output connect pin 3 to pin 1 (ground) in the cable connector.  
Input impedance 10 k balanced
Max input level +23 dBu
Output connector in parallel with input: XLR male pin 2+
pin 3-
Output impedance same as source
Continuously variable input level for maximum output from + 23 dBu
to -4 dBu
Subsonic filter down 12 dB @ 40 Hz
re 150 Hz level
Ultrasonic filter down 12 dB @ 50 kHz
re 10 kHz level
Crossover frequency 3,5 kHz
Crossover acoustical slopes > 12 dB / octave
Bass cut control operation range from -6 dB to 0 dB @ 100 Hz
The 'CAL' position is 0 dB cut control set fully clockwise.  

All data subject to change without prior notice
GENELEC Inc. - 7 Tech Circle - Natick - MA 01760 - USA - Tel +1 508 652 0900 - Fax +1 508 652 0909 - Email genelec.usa@genelec.com